(Including:40W/12V、50W/12V、60W/12V、150W/12V、300W/12V、1000W/24V、1200W/24V、1500W/24V、2000W/24V) |
| i 12V System |
|
|
|
W-120(40W/12V)
|
W-150(50W/12V)
|
W-180(60W/12V)
|
|
|
|
W-300(150W/12V)
|
W-600(300W/12V)
|
|
| The Converter “WRI” can transform the electrical energy of 12V direct current into the energy of
230V alternating current that can be used in appliances, such as TV, acoustics,
fax machine, haircut appliances, etc. |
| Other functions: overload
protection, short circuit protection, battery reverse link protection,
temperature protection and so on.
|
The
functions of protection: |
1. Overloading protection: When insert too many appliances and the
total power loads, the Converter will stop working within ten seconds. Then the
red indicator lamp will get light and the Converter will be fixed on the
protection state. Until reduce the load, turn the on-off of the power to the “OFF” over ten seconds and turn the on-off to the “ON”, then the Converter
will renew to work;
|
| 2. Short circuit protection: When the
interior of the appliance starts short circuit, the Converter will stop working
within one second and be fixed on the protection state. Till take the appliance
away, turn the on-off to the “OFF” over ten seconds and turn it to the “ON”,
then the Converter will renew to work;
|
| 3. Temperature protection: When the load is
too much or the temperature is too high, the temperature in the interior of the
Converter will get higher. When the temperature gets to
90℃
, the Converter
will stop working and be fixed on the protection state. Till you turn the
on-off to the “OFF” after reducing the load or improving the ventilation
condition and turn the switch “on-off“ to the “ON” after the interior temperature gets lower, then the Converter will renew to
work.
|
Technical Data: |
|
Specification: |
W-120 |
W-150 |
W-180 |
|
Model |
40W/12V |
50W/12V |
60W/12V |
|
Input voltage |
DC10—14V |
DC10—14V |
DC10—14V |
|
Input power |
≤40W |
≤50W |
≤60W |
|
Input current |
0.15—13A |
0.15—13A |
0.15—13A |
|
No-load loss |
≤1.5% |
≤1.5% |
≤1.5% |
|
Input voltage |
165—270V |
165—270V |
165—270V |
Output
frequency |
50—60HZ |
50—60HZ |
50—60HZ |
|
Efficiency |
75% |
75% |
75% |
|
|
|
Specification: |
W-300 |
W-600 |
|
Model |
150W/12V |
300W/12V |
|
Input voltage |
DC10—14V |
DC10—14V |
|
Input power |
≤150W |
≤300W |
|
Input current |
0.25—25A |
0.5—50A |
|
No-load loss |
≤1.5% |
≤1.5% |
|
Input voltage |
175—255V |
185—245V |
Output
frequency |
50—60HZ |
50—60HZ |
|
Efficiency |
78% |
80% |
|
|
|
|
|
W-1500(1500W/24V)
|
W-2000(2000W/24V)
|
|
“WRI”Solar Converter is equipped with Voltage and Current Meters
for battery, Indicator LCD for Electrical source, Power-off Protection
Indicator LED and AC Circuit Breaker in its surface and backside.
“WRI” Solar Converter other functions Reverse polarity
protection, overload protection, short circuit protection, thermal protection
and so on.
|
The functions of protection: |
1、 Reverse polarity protection: Incorrect
connection causes that no current passes the Converter, so it won’t ruin the Converter
(The hand of Voltage Meter will point to the reverse direction).
2、 Overloading
protection: When Converter is connected the excessive loads and the total power
of loads exceeds its tolerance, it will stop working within ten seconds. Then
the red LED will get light and the Converter will turn into the self-protection
state. After reduction of the load, turn the power switch “ on-off” to the “OFF” over ten seconds and then turn it into the “ON”, the Converter will
renew to work. (Meeting the malfunction, AC Circuit Breaker on the back of Converter
will automatically spring down. Before its startup, please push up the
Breaker.)
3、 Short circuit protection: When the
interior of the appliance starts short circuit, the Converter will stop working
within one second and turn into the self- protection state. Remove the malfunction;
turn the power switch “on-off” to the “OFF” over ten seconds, turn it to
the “ON”, then the Converter will renew to work. (Meeting the
malfunction, AC Circuit Breaker on the back of Converter will automatically
spring up. Before its startup, please press down the Breaker.)
4、Temperature
protection: For the load is too much or the environmental temperature is too high, the
interior temperature of Converter will get higher, so the Converter will stop
working and turn into the self-protection state. (Suggest to reduce the
quantity of loads or improve the ventilation, and then turn the switch “on-off”
to the “OFF”. After the interior temperature gets lower, then turn it to
the “ON”, the Converter will renew to work. |
Technical
Data: |
|
Specification: |
W-1000 |
W-1200 |
W-1500 |
W-2000 |
|
Model |
1000W/24V |
1200W/24V |
1500W/24V |
2000W/24V |
|
Input voltage |
DC22—28V |
DC22-28V |
DC22—28V |
DC22—28V |
|
Input power |
≤1000W |
1200W |
≤1500W |
≤2000W |
|
Input current |
1—45A |
0.5-50A |
1—65A |
0.15—13A |
|
No-load loss |
≤1.5% |
≤1.5% |
≤1.5% |
≤1.5% |
|
Input voltage |
200—240V |
195—245V |
200—240V |
165—270V |
Output
frequency |
50HZ |
50--60HZ |
50HZ |
50—60HZ |
|
Efficiency |
92% |
88% |
92% |
75% |
|
Dimension |
300×325×155 |
|
325×345×165 |
355×350×165 |
|
N.G |
11.2Kg |
|
14.3Kg |
19.2Kg |
|
| Ⅱ Sine wave Converter
series(1000W/24V、1500W/24V、2000W/24V) |
 |
 |
SW-1000
|
SW-2000
|
|
 |
SW-1500
|
|
Performance:
|
Sine
wave output : Can offer
sensibility load and other kind of loads, such as electric fan、refrigerator、air-condition、 electromotor and computer and so on.
Mono-microcomputer
controlls the solar Converters: It produces the wave’s shape and makes the frequency of the Converter
stable including auto-controll voltage.
Low
down the speed of open:
When we used high power loads, the Converter can low down the speed of open in
order to protect the electrical products on load and itself.
Overloading
protection: When Converter
is connected the excessive loads and the total power of loads exceeds its
tolerance, the Converter will be sound and the red LED will get light .Then the
Converter will stop working and turn into the self-protection state.
Short circuit protection: When
the interior of the appliance starts short circuit, the Converter will stop
output and lock up. Then the red LED will get light and the Converter will turn
into the self-protection state.
Discharge protection: When the voltage of the battery is lower
than21.5V, the Converter will be sound and the LED will get light. Then the Converter
will be stop output and lock up with in 5 minutes.
|
Technical Data |
|
Specification |
SW-1000 |
SW-1500 |
SW-2000 |
|
Model |
1000W/24V |
1200W/24V |
1500W/24V |
|
Output Voltage |
DC21.5—27.4V |
DC21.5—27.4V |
DC21.5—27.4V |
|
Input Current |
Max52A |
Max78A |
Max104A |
|
Output Voltage |
210—230V |
195—245V |
200—240V |
|
·Output Frequency |
50Hz± 1Hz |
50Hz± 1Hz |
50Hz± 1Hz |
|
Wave Distortion |
≤5% |
≤5% |
≤5% |
|
Overload Profiles |
Overload125% 60s |
Overload125% 60s |
Overload125% 60s |
|
Overload150% 7s |
Overload150% 7s |
Overload150% 7s |
|
Efficiency |
≥88% |
≥88% |
≥88% |
|
Output Wave |
Sine wave |
Sine wave |
Sine wave |
|
Dimension |
370×300×160mm |
400×320×170mm |
420*350*180mm |
|
N.G |
15.7Kg |
| |